logo
Wuhan Fengfan International Trade Co.,Ltd. 86-27-85615818 info@fengfan.net
TR-124 High Corrosion Protection Trivalent Chromium Passivator with U.S. GME00252 and GMW-3044 Standards Compliance

TR-124 High Corrosion Protection Trivalent Chromium Passivator with U.S. GME00252 and GMW-3044 Standards Compliance

  • Resaltar

    High Corrosion Protection Trivalent Chromium Passivator

    ,

    U.S. GME00252 Standard Trivalent Chromium Passivator

    ,

    GMW-3044 Standard Chemical Auxiliary Agent

  • Tipo
    pasivación amarilla trivalente
  • Artículo
    Agente auxiliar químico
  • Usar
    enchapado de zinc
  • Modelo
    Pasivador de cromo trivalente
  • Lugar de origen
    Porcelana
  • Nombre de la marca
    FENGFAN
  • Número de modelo
    TR-124,TR-125,TR-138
  • Cantidad de orden mínima
    Negociable
  • Precio
    Negociable
  • Detalles de empaquetado
    Embalaje de exportación estándar
  • Tiempo de entrega
    15-25 DÍAS LABORALES
  • Condiciones de pago
    LC, D/A, D/P, T/T, Western Union, MoneyGram
  • Capacidad de la fuente
    200000pcs/día

TR-124 High Corrosion Protection Trivalent Chromium Passivator with U.S. GME00252 and GMW-3044 Standards Compliance

TR-124 High Corrosion Protection Trivalent Chromium Passivator
TR-124 is a high-performance trivalent chromium passivator offering superior corrosion protection while meeting environmental standards.
Key Properties
  1. Trivalent chrome passivation process free from hexavalent chromium and oxidizers, certified by SGS international standards
  2. Provides excellent corrosion resistance for both yellowish and blue passivation treatments
  3. Passivation layer readily accepts organic dye staining
  4. Reduces wastewater treatment costs while complying with hexavalent chromium restrictions
  5. Extended usage life with recommended reflux washing water recycling
  6. Compliant with U.S. GME00252 and GMW-3044 standards
Process Flow
  • Plate zinc
  • Washing
  • Immerse in Nitric Acid (0.5%)
  • Immerse in TR-124
  • Wash with cool water
  • Wash with hot deionized water
  • Dry
Operation Parameters for Yellowish Passivation
Parameter Operating Range Optimal Setting
TR-124 Concentration 100-150 ml/L 125 ml/L
Immersion Time 45-80 seconds -
Temperature 55-80°C 60°C
pH Level 1.8-2.2 2.0 (adjusted with nitric acid or NaOH solution)